Commercial Duct Furnaces

Modine Duct Furnaces

Modine Duct Furnaces

Indoor Gravity and Power Vented

DFG/DFP

Standard Features:

  • C.S.A. certification - bearing C.S.A. logos
  • ETL certification
  • All units a minimum of 80% thermally efficient
  • 20-gauge aluminized steel cabinet
  • Certified to 3.0" W.C. external static pressure
  • MADE IN THE USA

Optional Features:

  • 409 stainless steel heat exchanger and burner
  • 409 stainless steel drip pan
  • Two-stage, mechanical modulation, and electronic modulation controls for either natural or propane gas
  • Building management compatible gas controls for modulation control using 0 - 10 Vdc or 4 - 20 mA input
  • High and/or low gas pressure switches

DFG/DFP Roof Top Gas Fired Nature vented Duct Furnace 80%

 
Model Input (BTUs) Output (BTUs) Air Volume CFM
DFG/DFP75 75000 60000 556-2778
DFG/DFP100 100000 80000 741-3704
DFG/DFP125 125000 100000 926-4630
DFG/DFP150 150000 120000 1111-5556
DFG/DFP175 175000 140000 1296-6481
DFG/DFP200 200000 160000 1481-7407
DFG/DFP225 225000 180000 1667-8333
DFG/DFP250 250000 200000 1852-9259
DFG/DFP300 300000 240000 2222-11111
DFG/DFP350 350000 280000 2593-11111
DFG/DFP400 400000 320000 2963-11111
 

Download Specs (PDF)

Modine Duct Furnaces

 

DFS

DFS Roof Top Gas-fired Power Vented Separated Combustion Duct Furnace 80%

 
Model Input (BTUs) Output (BTUs) Air Volume CFM
DFS 75 75000 60000 556-2778
DFS 100 100000 80000 741-3704
DFS 125 125000 100000 926-4630
DFS 150 150000 120000 1111-5556
DFS 175 175000 140000 1296-6481
DFS 200 200000 160000 1481-7407
DFS 225 225000 180000 1667-8333
DFS 250 250000 200000 1852-9259
DFS 300 300000 240000 2222-11111
DFS 350 350000 280000 2593-11111
DFS 400 400000 320000 2963-11111

duct furnace mississauga

 

Download Specs (PDF)

 

DBS/DCS

Standard Features:

  • ETL certification of the entire system unit
  • 18 gauge insulated aluminized steel blower cabinet with a baked-on polyester powder paint finish on exterior casing parts
  • Blower performance up to 3.0" W.C. external static pressure
  • Separate electrical, venting, and gas control access with fully gasketed doors

Optional Features:

  • DX or chilled water section with factory installed cooling coil
  • Double wall construction for blower and/or cooling cabinet
  • Dead-front disconnect switches
  • Two position, modulating, building pressure sensing, three position, building management (0 - 10 Vdc or 4 - 20 mA input) damper actuators
  • Blower and motor vibration isolation

DFS Roof Top Gas-fired Power Vented Separated Combustion Duct Furnace 80%

 
Model Input (BTUs) Output (BTUs) Air Volume CFM
DBS/DCS 75 75000 60000 556-2778
DBS/DCS 100 100000 80000 741-3704
DBS/DCS 125 125000 100000 926-4630
DBS/DCS 150 150000 120000 1111-5556
DBS/DCS 175 175000 140000 1296-5556
DBS/DCS 200 200000 160000 1481-6500
DBS/DCS 225 225000 180000 1667-6500
DBS/DCS 250 250000 200000 1852-9259
DBS/DCS 300 300000 240000 2222-11111
DBS/DCS 350 350000 280000 2593-12000
DBS/DCS 400 400000 320000 2963-12000
DBS/DCS 500 500000 400000 3086-9259
DBS/DCS 600 600000 480000 3704-11111
DBS/DCS 700 700000 560000 4321-12963
DBS/DCS 800 800000 640000 4938-14500
DBS/DCS 840 105000 840000 6481-12963
DBS/DCS 900 1200000 960000 7407-14500

Modine Duct Furnaces Toronto

 

Download Specs (PDF)

 

DBG/DCG

DBG/DCG Indoor Gas-fired Separated Combustion System Units

 
Model Input (BTUs) Output (BTUs) Air Volume CFM
DBG/DCG 75 75000 60000 556-2778
DBG/DCG 100 100000 80000 741-3704
DBG/DCG 125 125000 100000 926-4630
DBG/DCG 150 150000 120000 1111-5556
DBG/DCG 175 175000 140000 1296-5556
DBG/DCG 200 200000 160000 1481-6500
DBG/DCG 225 225000 180000 1667-6500
DBG/DCG 250 250000 200000 1852-9259
DBG/DCG 300 300000 240000 2222-11111
DBG/DCG 350 350000 280000 2593-12000
DBG/DCG 400 400000 320000 2963-12000
DBG/DCG 500 500000 400000 3086-9259
DBG/DCG 600 600000 480000 3704-11111
DBG/DCG 700 700000 560000 4321-12963
DBG/DCG 800 800000 640000 4938-14500
DBG/DCG 840 105000 840000 6481-12963
DBG/DCG 900 1200000 960000 7407-14500

duct furnace Toronto

 

Download Specs (PDF)

 

DBP/DCP

Standard Features:

  • C.S.A. certification – bearing C.S.A. logos
  • ETL certification
  • All units a minimum of 80% thermally efficient
  • 20-gauge aluminized steel cabinet
  • Certified to 3.0" W.C. external static pressure
  • Separate electrical, venting, and gas control access with fully gasket-installed doors
  • MADE IN THE USA

Optional Features:

  • 409 stainless steel heat exchanger and burner
  • 409 stainless steel drip pan
  • Two-stage, mechanical modulation, and electronic modulation controls for either natural or propane gas
  • Building management compatible gas controls for modulation control using 0 - 10 Vdc or 4 - 20 mA input
  • High and/or low gas pressure switches

DBP/DCP Indoor Gas-fired Separated Combustion System Units

 
Model Input (BTUs) Output (BTUs) Air Volume CFM
DBP/DCP 75 75000 60000 556-2778
DBP/DCP 100 100000 80000 741-3704
DBP/DCP 125 125000 100000 926-4630
DBP/DCP 150 150000 120000 1111-5556
DBP/DCP 175 175000 140000 1296-5556
DBP/DCP 200 200000 160000 1481-6500
DBP/DCP 225 225000 180000 1667-6500
DBP/DCP 250 250000 200000 1852-9259
DBP/DCP 300 300000 240000 2222-11111
DBP/DCP 350 350000 280000 2593-12000
DBP/DCP 400 400000 320000 2963-12000
DBP/DCP 500 500000 400000 3086-9259
DBP/DCP 600 600000 480000 3704-11111
DBP/DCP 700 700000 560000 4321-12963
DBP/DCP 800 800000 640000 4938-14500
DBP/DCP 840 105000 840000 6481-12963
DBP/DCP 900 1200000 960000 7407-14500

 

Download Specs (PDF)

 

HFG/HFP

Standard Features:

  • C.S.A. certification - bearing C.S.A. logos
  • ETL certification
  • All units a minimum of 80% thermal efficient
  • 18-gauge aluminized steel cabinet with a baked-on polyester powder paint finish on exterior casing parts
  • Certified to 3.0" W.C. external static pressure
  • MADE IN THE USA

Optional Features:

  • 409 stainless steel heat exchanger and burner
  • 409 stainless steel drip pan
  • Two-stage, mechanical modulation, and electronic modulation controls for either natural or propane gas
  • Building management compatible gas controls for modulation control using 0 - 10 Vdc or 4 - 20 mA input
  • High and/or low gas pressure switches

HFG/HFP Roof Top Gas-fired Nature vented Duct Furnace 80%

 
Model Input (BTUs) Output (BTUs) Air Volume CFM
HFG/HFP 75 75000 60000 556-2778
HFG/HFP 100 100000 80000 741-3704
HFG/HFP 125 125000 100000 926-4630
HFG/HFP 150 150000 120000 1111-5556
HFG/HFP 175 175000 140000 1296-6481
HFG/HFP 200 200000 160000 1481-7407
HFG/HFP 225 225000 180000 1667-8333
HFG/HFP 250 250000 200000 1852-9259
HFG/HFP 300 300000 240000 2593-11111
HFG/HFP 350 350000 280000 2593-11111
HFG/HFP 400 400000 320000 2963-11111

 

Download Specs (PDF)